Page 235 - ZSi-Foster-Engineering-Catalog
P. 235

 W7550 to W7552
Concrete Insert
Part No.
W7550 W7551 W7552
Size
4" (102mm) 6" (152mm) 8" (203mm)
Anchor End Caps
W5958
Wt. / CPCS 74# (33.5 Kg) 99# (44.9 Kg) 124# (56.2 Kg)
Allowable Load Lbs. (kN) 500 (2.22 kN) 750 (3.34 kN) 1000 (4.45 kN)
23⁄8"
60mm
Part No.
W7553 * W7554 W7555 W7556 W7557 W7557A W7558 W7559 W7560 W7561 W7562 W7563 W7564 W7565 W7566 W7567 W7568 W7569 W7570
Size
12" (305mm) 16" (406mm) 20" (508mm) 24" (610mm) 32" (813mm) 36" (914mm) 40" (1016mm) 4' (1.2m)
5' (1.5m) 6' (1.8m) 7' (2.1m) 8' (2.4m) 9' (2.7m) 10' (3m) 12'(3.6m) 14' (4.2m) 16' (4.8m) 18' (5.4m) 20' (6.1m)
End Cap Number W5958
Wt. / CPCS
163# (73.9 Kg) 213# (96.6 Kg) 263# (119.2 Kg) 313# (141.9 Kg) 414# (187.7 Kg) 464# (210.4 Kg) 510# (231.3 Kg) 615# (278.9 Kg) 766# (347.4 Kg) 916# (415.4 Kg) 1079# (489.4 Kg) 1218# (552.4 Kg) 1368# (620.5 Kg) 1519# (689 Kg) 1820# (825.5 Kg) 2122# (962.5 Kg) 2423# (1099 Kg) 2725# (1236 Kg) 3026# (1372.5 Kg)
Allowable Load Lbs. (kN)
W5938 End Cap
1 3⁄8"
35mm
1"
25mm
* W7553 utilizes tab channel (punched & anchor caps)
Continuous Concrete Inserts W800 - 15⁄8" x 1" - 12 Gauge
Technical Gamma Rooftop Concrete Beta Clamps Loop & Ring Spring Electrical Pipe & Conduit General Channel Nuts Channel Introduction Data Pads Supports Inserts & Z-Clamps Clamps Steel Fittings Supports Fittings & Hardware
Refer to page 232 for continuous concrete insert part number selection chart to build complete part number based on desired options.
W7553 to W7570
12 Gauge, Continuous Concrete Inserts
When ordering specify finish. Available in plain, pre-galvanized, hot dip galvanized after fabrication, 304 and 316 stainless steel.
4"
W5938
1500
(6.67 kN)
Refer to page 232 for continuous concrete insert part number selection chart to build complete part number based on desired options.
ZSi-Foster Engineering Catalog
WARNING: These products can expose you to chemicals including lead, which is known to the State of California to cause cancer, and which is known to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
– 235 –
Rigid Foam Filler
2"
51mm
1"
25mm
1 5⁄8"
41mm
3⁄4"
19mm
1 5⁄8"
41mm
102mm
102mm
W800
4"
4"
102mm
Concentrated load on the end 2" (51mm)
of W7552 thru W7570 should not exceed
750#. Inserts must be surrounded by
sufficient concrete to conform to design
shear stress. Concrete insert should be
nailed to form every 16" to 24" (406mm to 635mm)